HomeProductsOutdoor Telecom DC Power Supply Wall Mount
  • Wall-Mounted DC Switching Power Supply
  • DC Switching Power Supply
  • DC Switching Power Supply
  • Wall-Mounted DC Switching Power Supply
  • DC Switching Power Supply
  • DC Switching Power Supply

Outdoor Telecom DC Power Supply Wall Mount

3kW / 5kW / 7.5kW ; Max Capacity: 200A
Overviews
The Wall Mount Telecom Power Supply is an integrated outdoor power cabinet, integrating AC input power distribution, lightning protection unit, switch rectifier, battery pack, DC output power distribution unit, FSU, and outdoor integrated chassis.
Output Capacity 3kW / 5kW / 7.5kW
Installation Ways Wall-mounted, Floor-standing, Pole-mounted
Max Capacity 200A
Input Power Factor 0.8 / 1
  • Features

  • Specifications

  • Applications

  • Download

Integration of System Functions
It integrates functions of communication power supply, AC/DC power distribution, temperature control, monitoring, lightning protection and grounding, etc.
Battery Management Functions
It has a comprehensive battery management system, including functions like battery low-voltage protection and load disconnection. It can also achieve functions such as temperature compensation, automatic voltage regulation, current limiting, battery capacity calculation, and energy-saving in standby mode.
Communication and Monitoring Features
The power supply system is designed in a networked manner, providing multiple communication interfaces such as RS232/RS485 and dry contacts. It has a flexible networking capability and can realize remote monitoring and unattended operation.
Protection and Operation Characteristics
It has a complete lightning protection design on both the AC and DC sides, as well as comprehensive fault protection and fault alarm functions. The operation and maintenance of the power supply system can be carried out on the front side. It is convenient to operate, easy to install and maintain.

Read More
Output 220Vac±1% 220Vac±2%(Inverter mode)
Frequency 50Hz±5%Hz
Waveform Pure Sinewave
Waveform Distortion Rate Below 3% (Linear load at full load)
Power Factor 0.8
Efficiency (Inverter) Mode >90%
Conversion time  
Power outage or restoration 0ms <10ms
System Noise  
Noise <50db@1 m <55db@1 m
Alarm  
Battery discharge WITH
UPS abnormal WITH
Working environment  
Temperature -20~50℃ (Outdoor); 0~40℃ (Indoor)
Humidity 0~95% (non-condensing)
Dimension  
W*H*D(mm) 530*460*850 / 550*560*850 / 565*600*980 530*445*850
Read More

It is applied in communication systems and is suitable for occasions with a wide range of power grid fluctuations, such as base stations, small and medium-capacity switching offices, satellite communications, and data communications.