Solution de refroidissement liquide au niveau des rangées

350kW, 600kW ; Cooling Water
Aperçus
UN modular liquid cooling system deployed between cabinet rows, with 350kW-600kW cooling capacity. Adopts dual-circuit heat exchange (primary: cooling water; secondary: 25% ethylene glycol).
Features redundant key components (pumps, sensors) and leak detection, supports online maintenance and remote management. Ideal for cold-plate data centers (10+ liquid cabinets), CPU/GPU-intensive HPC clusters, and medium-large GPU AI centers.
  • Caractéristiques

  • Caractéristiques

  • Applications

  • Télécharger

Scénarios d'application

  • Cold plate liquid cooling data centers, suitable for modular deployment of 10+ liquid cooling racks (or above).
  • High-Performance Computing (HPC) clusters, such as CPU/GPU-intensive scientific computing (e.g., weather simulation, gene sequencing).
  • Intelligent computing centers with medium-to-large GPU clusters, used for AI large and small model training.

Product Features

  • High Cooling Capacity: Offers cooling capacity ranging from 200kW to 550kW, compatible with various rack dimensions.
  • High System Reliability: Key components (e.g., pumps, control sensors, filters) and independent leak detection systems adopt redundant configurations, ensuring continuous cooling during maintenance or faults.
  • Online Maintenance: Real-time online water quality monitoring and online coolant replacement are supported, ensuring the system operates in optimal condition.
  • Remote Management: Integrates industrial communication protocols such as Modbus and BACnet, supporting remote data monitoring and fault early warning to improve data center management efficiency.
En savoir plus
Modèle SY-CDU-RW-600 SY-CDU-RW-350
Heat Exchange Capacity kW 600 350
Primary Side Circulation Medium / Cooling water Cooling water
Designed Inlet/Outlet Liquid Temperature 35/45 35/45
Circulation Flow Rate m³/h 52.26 30.387
Interface Size mm φ89*2.0 φ76.2*2.0
Water Pressure Drop KPa ≤120 ≤120
Secondary Side Circulation Medium / 25% ethylene glycol 25% ethylene glycol
Designed Inlet/Outlet Liquid Temperature 50/40 50/40
Outlet Liquid Temperature Range 35~50 35~50
Available Head KPa ≥120 ≥120
Circulation Flow Rate m³/h 55.49 31.867
Number of Water Pumps Set 1 2
Interface Size mm φ89*2.0 φ76.2*2.0
Puissance nominale kW 11.6 4.8
Operating Weight kg 550 600
Overall Dimensions  mm 600*1200*2200 600*1200*2000
En savoir plus
En savoir plus
En savoir plus

Contactez-nous

Contactez-nous pour obtenir une assistance produit et technique

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.
WhatsApp

Laissez un message!

Laissez un message!

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.

Ouvrir une conversation sur WhatsApp ?

Annuler D'ACCORD