High Energy Efficiency
The unit integrates variable air volume and water flow control with hot-cold channel isolation, enabling energy-efficient operation. With multiple operating modes, it automatically selects the optimal setting based on indoor and outdoor conditions, effectively lowering the data center’s PUE value.
Structural Design
Featuring a novel design, the unit embeds high-capacity cooling coils and fans within the data center’s isolation wall, creating a sealed hot air return channel. Its three-dimensional front facade offers a sleek appearance. The separation of cooling coils and fans into independent modules expands the size and specification options.
Modular Prefabrication
Designed modularly, each wind wall unit can operate independently or be combined flexibly. Boasting high cooling capacity, these units allow easy addition or removal of modules, adapting seamlessly to changing room loads.
Redundant Design
The fan redundant design can meet different cooling requirements and is easy to install and maintain.
DC FAN
It uses high-efficiency DC fans, which have the advantages of energy saving, low noise, and continuously adjustable air volume.
Electric two-way valve
Adopt first-line brand, product performance is excellent, high sensitivity, easy to replace, and effective in regulating water flow.
Cold water coil
Use I-shaped cold water coil to increase the heat exchange area and make the airflow more uniform.
En savoir plus -
FO. GBE Modular Fan Wall Unit Parameters
Modèle
FO. GBEUnité 1500 R-H 2000 R-H 2500 R-H 3000 R-H Cooling Conditions 37°C-30%RH 37°C-30%RH 27°C-30%RH 37°C-30%RH Total Cooling Capacity kW 150.1 200.1 250.1 300.1 Sensible Cooling Capacity kW 150.1 200.1 250.1 300.1 Inlet/Outlet Water Temp °C 15/21 15/21 15/21 15/21 Water Flow Rate m³/h 21.51 28.68 35.84 43.01 Pressure Drop kPa 115 120 125 130 Ventilateur EC Quantité pcs 4 4 4 6 Air Supply Volume m³/h 35000 40000 49000 56000 Residual Pressure Pa 200 Puissance nominale kW 7 8 10.1 13.2 Dimensions Longueur mm 2400 2400 3000 3000 Largeur mm 1100 1100 1100 1100 Hauteur mm 2150 2150 2150 2150 Connections DN 65 65 65 65 Electrical Parameters Puissance d'entrée 380V±10%50HZ±3HZ FO. WL Wind Wall Air Conditioning Unit Parameters
Paramètre Unité FO.WL-600 FO.WL-300 Cooling Conditions 37°C-30%RH 37°C-30%RH Total Cooling Capacity kW 60.1 30.3 Sensible Cooling Capacity kW 60.1 30.3 Inlet/Outlet Water Temp °C 18/24 18/24 Water Flow Rate m³/h 8.61 4.32 Pressure Drop kPa 61 41 Ventilateur EC Quantité pcs 78 39 Air Supply Volume m³/h 14 70 Raised Power kW 1.04 0.39 Dimensions Longueur mm 1200 600 Largeur mm 2000 2000 Hauteur mm 2200 2200 Poids kg 165 95 Connections DN 32 32 Electrical Parameters Puissance d'entrée - 220V ±10% 50Hz ±3Hz En savoir plus -
- Innovative Energy-saving Data Center
The wind wall unit is combined with the building structure of the computer
room, and a fan matrix air supply form can be adopted, which fully utilizes the
advantages of closed cold and hot channels, with high density and low energy
consumption. - Energy-saving Transformation of Data Centers
The combination of the computer room structure and the heat dissipation system
can adopt direct fresh air or a mixed solution of fresh air and return air cooling.
The airflow organization of the wind wall is better and the heat exchange effect is
better. Under the same cooling demand, the air volume demand is reduced, the
fan power consumption is further reduced, and the energy saving effect can reach
more than 10%. - Data Center with Coordinated Building Structure Design
Combined with the characteristics of the building structure, a variety of personalized
structural forms can be adopted to cooperate with the overall designed data center. - Areas with Low Temperatures All Year Round
According to the characteristics of low temperature, the wind wall unit system can
adopt fresh air direct cooling, fresh air return air mixed cooling, and fresh air
indirect evaporative cooling for better energy saving effect.