Capacity | 160kVA/144kW - 600kVA/540kW |
Output Voltage | Line Voltage: 380×(1±1%)AC or Phase Voltage: 220×(1±1%)AC |
Output PF | 0.9 |
Frequency Range | 50 / 60Hz ± 10% |
Industrial Frequency Durable UPS 160-600kVA
Power Factor: 0.9 ; 160 - 600kVA
Overviews
SY-G Series is a high-end 3 Phase Input/Output transformer based UPS system. It has significantly improved the efficiency and reliability. With Multiple Digital Control Modules, such as DSP, MCU, and CPLD, SY-G can be non-prioritized paralleled up to 8 units to lower operating costs without compromising reliability, performance, and availability.
Features
Specifications
Applications
Download
-
- Advanced Rectifier and IGBT Technology:Features advanced rectifier and IGBT technology. Input THDI≤4%, Input Power Factor≥0.99 to save more energy. With optional filters, input power factor can be upto >0.99 and THDI<4.5%.
- Wide Input Characteristics:Has a wide input voltage range, high adaptive capacity, and good generator – compatibility.
- Load – related Performance:Exhibits high load compatibility, short – circuit protection, and high overload ability. Output Power Factor is 0.9 without lagging.
- Fault Detection:Can self – evaluate and alarm in case of phase misconnection or loss.
- Full – digitized Control:The RP – N series uses full – digitized control for all power conversion sections during operations, enhancing system reliability.
- Cooling System Design:Features internal parallel redundancy design for cooling fans.
- Output Transformer:Has a built – in output isolated transformer to reduce impacts and interferences from load harmonic wave current and N – wire voltage.
- Component Quality:90% of system components are from international brands. All devices are aged and tested for 24 hours before leaving the factory.
- Communication Interfaces:Integrates multiple communication interfaces like RS232, RS485, dry contact, and EPO. Optional SNMP communication adapter is available.
- Maintenance and Connection:Adopts front – maintenance design and is available for top connections with protection devices.
- User Interface:Features an intuitive user interface with a large dot – matrix LCD screen and a multi – functional keyboard.
Read More -
Model RP1600L33-N RP2000L33-N RP2500L33-N RP3000L33-N RP4000L33-N RP5000L33-N RP6000L33-N Capacity 160KVA/144KW 200KVA/180KW 250KVA/225KW 300KVA/270KW 400KVA/360KW 500KVA/450KW 600KVA/540KW Host Machine Specification UPS Structure Online Double Conversion Appearance Low Frequency with Output Isolated Transformer Overall Efficiency (AC-AC) 94% (With Optional Accessories) ECO 98% Noise (In 2 Meters) 67dB Working Temp. 0-40℃ Storage Temp. -15 ~ 50℃ (without batteries) Humidity < 95% Non-Condensing National Standard IEC60950-1,IEC62040-1-1 International Standard IEC62040-2,IEC62040-3 Parallel Redundancy Parallel Redundancy Upto 8 Units Protection Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low DC Start Available Generator Compatibility Available Display LCD Display (Multi-Language with all kinds of messages)+LED Mute Auto Cabinet Standard IP20 Cooling System Intelligent Speed Control Cooling Fan Elevation <1500M, Without Derated Rectifier Specification Input Voltage 380/400/415Vac+N+W (3 phase + PE) Input Voltage Range 298-498Vac Input Frequency Range 50/60Hz±10% Soft-Start 5-600 Seconds, Adjustable Input PF 0.95 (With Optional Input Wave Filter) THDI < 5% (With Optional Accessories) Output Specification Output Voltage Line Voltage: 380×(1±1%)AC or Phase Voltage: 220×(1±1%)AC Output PF 0.9 Output Voltage Regulation 380Vac±1%(Static Load); 380Vac±2%(50-0% Sudden Change); 380Vac±3%(100-0% Sudden Change) Voltage Dynamic Response ±5%,(0~100% Sudden Change) Voltage Dynamic Response Tim <5ms Synchronization Range ±5% Output Freq ±0.02% (BAT Mode) THD < 1% (Linear Full Load), < 3% (Non-Linear Full Load) 3 Phase Unbalanced Allow 3 Phase 100% Unbalanced Output Volt. Unbalanced ≤1% (Balanced Load), ≤2% (50% Balanced Load) Input/Output Phase Swift ≤1° (Balanced Load), ≤2° (50% Balanced Load) Frequency Tracking Range 45-65Hz Output Waveform Pure Sine Wave Overload With output PF 0.9, 105%: Long time Operation,110%: 1 Hour,125%: 10 Mins,150%:1 Min Crest Ratio 3∶1 Short-Circuit Circuit Auto-Protection, Bypass Switch Tripping Output Abnormal INV. Output Auto-Locked Protection Bypass Specification Static Bypass Transfer Time 0ms Static Bypass Range 380/400/415Vac (±10%,±15%,±20% Selectable) 3 Phase+N (3 Phase+N+PE) Frequency Range 50/60Hz±10% Bypass -> INV Transfer Time 2ms Bypass Overload Ability 200%: 5 Mins; 1000%:10 Seconds Manual Maintenance Bypass Available Battery Specification Type Sealed Lead Acid Maintenance Free Std. Model Rated Volts/Units 12V,384Vdc/32 Units Float Charge Voltage Equalized Charge, Float Charge, Intelligent Battery Management BAT Low Shutdown Protection Communication Specification Communication Port RS232/SNMP/485/Dry Contact (Optional Accessory) Remote Software Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control Physical Parameters Size mm(D) 855 855 855 855 955 Size mm(H) 1900 1900 1900 1900 1900 Size mm(W) 6 pulse 1245 1640 2265 -- -- Size mm(W) 12 pulse 1770 2265 2265 2615 2865 Net Weight Kg(6 pulse) 1075 1580 2105 -- -- Net Weight Kg(12 pulse) 1685 2090 2500 2850 3130 Note: Specifications are subject to change without further notice.