Heat Exchange Capacity: 50kW, 80kW
Overviews
A compact, cabinet-based liquid-liquid cooling system, designed for small-scale or distributed liquid cooling scenarios (2+ liquid cooling cabinets). It uses dual liquid circuits (primary: cooling water; secondary: 25% ethylene glycol) for heat exchange, with 50kW-80kW cooling capacity and supports 19/21-inch standard racks.
Key CDU components (sensors, pumps) adopt redundant designs; it features small size, no major room modification, and easy expansion by single cabinet. Ideal for small-medium data centers, space-constrained edge computing facilities, and cold-plate liquid cooling scenarios needing flexible capacity increase.
  • Features

  • Specifications

  • Applications

  • Download

Application Scenarios

  • Small and medium-sized data centers, suitable for small-scale or distributed deployment of liquid-cooled computing scenarios (applicable to 2+ liquid cooling racks or above).
  • Edge computing facilities in space-constrained environments that require high-performance liquid cooling for edge computing.
  • Cold plate liquid-cooled computing application scenarios requiring flexible expansion, allowing capacity increase with a single rack as the minimum unit.

Product Features

  • Multi-Scenario Compatibility: Available in two size specifications (19-inch and 21-inch) to adapt to different application scenarios.
  • High Heat Density Deployment: The standard rack supports a power density ranging from 50kW to 200kW.
  • High Redundancy Design: Key components of the CDU (e.g., sensors, pumps) adopt redundant designs to maximize operational safety.
Read More
Model SY-CDU-RK-50 SY-CDU-RK-80
Heat Exchange Capacity kW 50 80
Primary Side Circulation Medium / Cooling water Cooling water
Designed Inlet/Outlet Liquid Temperature 35/45 35/45
Circulation Flow Rate m³/h 4.32 6.91
Interface Size mm φ31.8*1.5 φ38.1*1.5
Water Pressure Drop KPa ≤100 ≤100
Secondary Side Circulation Medium / 25% ethylene glycol 25% ethylene glycol
Designed Inlet/Outlet Liquid Temperature 50/40 50/40
Outlet Liquid Temperature Range 35~50 35~50
Available Head KPa ≥120 ≥150
Circulation Flow Rate m³/h 4.56 7.29
Interface Size mm φ31.8*1.5 φ38.1*1.5
Rated Power kW 0.8 1.4
Net Weight kg 75 85
Overall Dimensions  mm 450*850*175 536*900*175