Capacity | 1 kVA/0.8 kW - 10 kVA/8 kW |
Input Phase | Single Phase with Ground |
Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Frequency Range | 47~53 Hz or 57~63 Hz |
Rack-Mounted 0.8 PF High Frequency UPS
Power Factor: 0.8 ; 208/220/230/240 VAC
Overviews
The SYM Series Standard rack-mounted structure design, compatible with tower installation. 110V to 300V wide input power range, adaptable to harsh power grid environment. Zero conversion time between AC mode and battery mode. Input zero live wire detection function. With voltage surge protection function and strong anti-interference function.
Features
Specifications
Applications
Download
-
• Realize online double conversion
• Microprocessor control technology ensures high reliability input power factor correction
• Output power factor 0.8
• Wide input voltage (110V to 300V)
• Efficient frequency conversion mode
• ECO mode provides energy saving effect (only for 1-3K models compatible with generator input
• Long-term backup charging current up to 6A
Read More -
Model SYRT 1kVA SYRT 2KVA SYRT 3KVA SYRT 6KVA SYRT 10KVA Phase single phase grounded Capacity 1000VA/800W 2000VA/1600W 3000VA/2400W 6000VA/4800W 10000VA/8000W Iutput Rated voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC Voltage range 55-145VAC or 110-300VAC at 50% load
85-140VAC or 160-280VAC at 100% load110-300 VAC±3% at 50% load
176-300VAC±3% at 100% loadFrequency range 40Hz~70Hz 46Hz~54 Hz or 56Hz~64 Hz Power factor ≧0.99@100% load Output Rated voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC Voltage range (battery mode) ±1% ±1% Frequency range (synchronous correction range) 47~53 Hz or 57~63 Hz 46Hz~54 Hz or 56Hz~64 Hz Frequency range (battery mode) 50Hz±0.25Hz or 60Hz±0.3Hz 50Hz±0.1Hz or 60Hz±0.1Hz Current wave front ratio 3:1 Harmonic distortion ≦3%THD (linear load); ≦5%THD (nonlinear load) ≦3%THD (linear load); ≦5%THD (nonlinear load) Conversion time Mains mode to battery mode none Inverter to bypass 4 milliseconds (under standard conditions) 0 milliseconds Waveform (battery mode) pure sine wave Efficiency Mains power mode 88% 89% 90% 92% 93% Battery mode 83% 87% 88% 90% 91% Battery Standard unit Battery Type 12V/9AH 12V/9AH 12V/9AH 12V/9AH Quantity 2 4 6 16 pieces 20 pieces 16 pieces 20 pieces Standard charging time Charge to 90% in 4 hours Charge to 90% in 9 hours Maximum charging current 1.0A (maximum) Default: 1.0 A, Max.: 2.0A Charging voltage 27.4VDC±1% 54.7VDC±1% 82.1 VDC±1% 218.4VDC±1% 273VDC±1% 218.4VDC±1% 273VDC±1% Long backup unit Battery Type Match multiple battery boxes according to actual application quantity 2 3 4 6 6 8 16~20(adjustable) Maximum charging current 1.0A/2.0A/4.0A/6.0A 1A/2A/4A/6A (adjustable, 6A is only suitable for 16 batteries) Charging voltage 27.4VDC±1% 41.0VDC±1% 54.7VDC±1% 82.1 VDC±1% 82.1 VDC±1% 109.4VDC±1% 218.4VDC±1% (based on 16 pcs) Display Instructions LCD or LED display Load size, battery capacity, mains mode, battery mode, bypass mode, fault indication Warning sound Battery mode Beeps every 4 seconds Battery low One sound every 1 second Overload One sound every 1 second Fault Continuous beeping Physical Properties Standard machine Dimensions, depth × width × height (mm) 310×438×88[2U] 410×438×88[2U] 630×438×88[2U] Host: 530x438x88[2U] Battery Kit: 668x438x88[2U] Host: 530x438x88[2U] Battery Kit: 580×438×133 [2U] Host: 580x438x133[3U]
Battery kit: 580x438x133[3U]Net weight (kg) 12 19 29.3 Host: 15
Battery Kit: 48Host: 15
Battery Kit: 61Host: 18 Battery Kit: 51 Host: 18 Battery Kit: 61 Long lasting machine Dimensions, depth × width × height (mm) 310×438×88[2U] 410×438×88 [2U] 500×438×88[2U] 580×438×133 [3U] Net weight (kg) 9 12 14.2 15 18 Usage Environment Temperature and humidity Relative humidity 20-90% and temperature 0-40°C (no condensation) Relative humidity 0-95% and temperature 0-40°C (non-condensation) Noise Less than 50dBA@1 meter Less than 55dBA@1m Less than 58dBA@1m Control Management Intelligent RS-232/optional USB Support Windows*2000/2003/XP/ Vista/2008, Windows*7/8, Linux, Unix, and MAC Optional SNMP Power management supports SNMP management and network management *When the UPS is set to constant voltage and constant frequency mode, the output power will be reduced by 40%. When the output voltage of the UPS is set to 208VAC, the output power will be reduced by 10%. **When the number of internal batteries is changed to 16-19, the machine will reduce the output according to the following formula: P=PratingX(N/20×100%). ***If the machine is installed at an altitude of more than 1000 meters, the output power will be reduced by 1% for every 100M increase. The current product specifications are subject to change without further notice. Read More -
- Medium-sized Data Centers: Specifically designed for medium-sized data centers housing hundreds of servers, its standard rack design facilitates unified installation and management with servers. Through parallel operation technology, redundant configuration can be achieved, greatly enhancing the reliability of power supply.
- Enterprise Core Machine Rooms: Aiming at enterprise core machine rooms, it can meet the stringent requirements of key business systems such as ERP and CRM for power continuity and stability. Its high-density design saves space, and it has strong scalability, being able to adapt to the changes in power demand brought about by the growth of enterprise businesses.
- Communication Base Station Convergence Machine Rooms: Used in communication base station convergence machine rooms, it can provide stable and efficient power for devices such as switches and transmission equipment. The high-frequency technology reduces energy consumption, and the remote monitoring function enables operators to promptly grasp the device status, ensuring the stable operation of the communication network.
Read More -
Read More
Contact Us
Reach Out for Product and Technical Support