| MODEL |
SYRT WinnerPro+1kVA |
SYRT WinnerPro+2kVA |
SYRT WinnerPro+3kVA |
SYRT WinnerPro+6kVA |
SYRT WinnerPro+10kVA |
| Phase |
Single phase with ground |
|
|
1000 VA/900W |
2000 VA/ 1800W |
3000 VA/2700 W |
6000VA/5400W |
10000 VA/9000W |
| INPUT |
| Nominal Voltage |
110/115/120/127VAC or 208/220/230/240VAC |
208/220/230/240VAC |
| Input Voltage Range |
60-145 VAC or 120-300 VAC (Based on load at 50%)
90-145 VAC or 180-300 VAC (Based on load at 100%) |
110-300 VAC (Based on load at 50%).
176-300 VAC (Based on load at 100%) |
| Frequency Range |
40 Hz ~ 70 Hz |
46~54 Hz or 56~64 Hz |
| Power Factor |
≧0.99 @ Nominall Voltage (100% load) |
| OUTPUT |
| Output Voltage |
110/115/120/127VAC or 208/220/230/240VAC |
208/220/230/240VAC |
| Voltage Regulation |
±1% |
| Frequency Range(Synchronized Range) |
47~ 53 Hz or 57 ~63 Hz |
46Hz~54 Hz or 56Hz~64 Hz |
| Frequency Range(Batt. Mode) |
50 Hz or 60Hz±0.5% |
50 Hz±0.1 Hz or 60 Hz±0.1 Hz |
| Current Crest Ratio |
3:1 |
| Harmonic Distortion |
≦3%THD(Linear Load)
≦6% THD(Non-linear Load) |
≦3 %THD (Linear Load)
≦5 % THD(Non-linear Load) |
Transfer
Time |
AC Mode to Battery Mode |
Zero |
0 ms |
| Inverter to Bypass |
4m s (Typical) |
0 ms |
| Waveform(Batt. Mode) |
Pure Sinewave |
| EFFICIENCY |
| AC Mode |
88% |
89% |
90% |
92% |
93% |
| Battery Mode |
83% |
87% |
88% |
90% |
91% |
| BATTERY |
Standard
unit |
Battery Type |
12V/9Ah |
12V/9Ah |
12 V/9Ah |
12 V/9Ah |
| Numbers |
2 |
3 |
4 |
6 |
16 |
20 |
16 |
20 |
| Typical Recharge Time |
4 hours recover to 90% capacity |
9 hours recover to 90% capacity |
| Charging Current(max.) |
1A |
1A/2A(Adjustable) |
| Charging Voltage |
27.4VDC±1% |
41.0VDC±1% |
54.7 VDC±1% |
82.1 VDC ±1% |
218.4 VDC±1% |
273VDC ±1% |
218.4 VDC±1% |
273VDC±1% |
Long backup
unit |
Battery Type |
Depending on applications |
| Numbers |
3 |
6 |
6 |
16~ 20 (Adjustable) |
| Charging Current(max.) |
1.0A/2.0A/4.0A/6.0 A |
1A/2A/4A/6A(Adjustable,6Ais only available for 16 pcs batteries) |
| Charging Voltage |
41.0VDC±1% |
82.1 VDC±1% |
82.1VDC±1% |
218.4 VDC±1%(Based on 16 pcs batteries) |
| INDICATORS |
| LCD |
Load level, Battery level,AC mode, Battery mode, Bypass mode, and Fault indicators |
| ALARM |
| Battery Mode |
Sounding every 4 seconds |
| Low Battery |
Sounding every second |
| Overload |
Sounding twice every second |
| Fault |
Continuously sounding |
| PHYSICAL |
Standard
unit |
Dimension,DxWxH (mm) |
310×438
×88 |
410×438×88 |
630×438×88 |
UPS Unit:
500×438×88[2U]
Battery Pack:
668x438x88[2U] |
UPS Unit:
500x438x88[2U]
Battery Pack:
580x438x133[3U] |
UPS Unit:
580×438×133[3U]
Battery Pack:
580x438x133[3U] |
| Net Weight(kgs) |
12 |
14.1 |
19 |
29.3 |
UPS Unit:15
Battery Pack:48 |
UPS Unit:15
Battery Pack: 61 |
UPS Unit: 18
Battery Pack:51 |
UPS Unit :18
Battery Pack: 61 |
Long backup
unit |
Dimension,DxWxH (mm) |
310×438×88 |
410×438×88 |
460×438×88 |
500×438 ×88[2U] |
580×438×133[3U] |
| Net Weight(kgs) |
9 |
12 |
14.2 |
15 |
18 |
| ENVIRONMENT |
| Humidity |
20-90% RH @0 - 40℃ (Non-condensing) |
0-95% RH @0-40°C(non-condensing) |
| Noise Level |
Less than 50dB @ 1 Meter |
Less than 55dB @ 1 Meter |
Less than 58dB @ 1 Meter |
| MANAGEMENT |
| Smart RS-232/USB |
Supports Windows®2000/2003/XP/ Vista/2008,Windows®7/8/10, Linux and MAC |
| Optional SNMP |
Power management from SNMP manager and web browser |