Row Modular Data Center Multiple Cabinets
· As a top solution for small data centers, Modular data center simplifies construction, solves professionalism, standardization, speed, and scalability issues. It offers fast build-up, high energy efficiency, diverse configurations, and easy maintenance.
Features
Specifications
Applications
Download
-
• Simplicity: The MC2000 series features a standard modular structural design for the overall system. All sub-components are highly universal. Sub-modules are pre-installed in the factory. The equipment cabinets and IT cabinets are combined on-site. With low requirements for the installation site, the equipment can be put into use quickly after arrival. During operation, only one monitoring and management system is needed, eliminating the need to deal with multiple interfaces.
• Efficiency: The MC2000 series offers three types of enclosed channels: fully enclosed cold and hot aisles (recommended), closed cold aisle, and natural cooling. Cold aisle enclosure can significantly improve the utilization of cooling capacity. Hot aisle enclosure can enhance the cooling efficiency of air conditioners. Full enclosure of both cold and hot aisles improves both cooling capacity utilization and air-conditioner cooling efficiency, with a leading PUE value in the industry.
• Flexibility: With a standard modular structural design for the overall system and highly universal sub-modules, various solutions can be achieved through combination according to needs. Easy expansion can be realized in the later stage.
• Reliability: The fully enclosed cold and hot aisles are self-contained and adaptable to various environmental sites. The standardized architecture design of the overall system avoids system design problems. The system has a fault-tolerant design, ensuring high reliability. The separation of strong and weak current reduces electromagnetic interference. It has passed the seismic performance test with power on at intensity levels 8 and 9.
• Intelligence: The MC2000 series has a built-in monitoring system and a 10.1-inch touch-screen. You can directly read power, AC, environmental, and UPS parameters on it or monitor them remotely. It can connect to a superior platform for multi-site management.Each MC2000 cabinet has an intelligent LED light strip. It’s blue (normal) at 18 – 27℃, turns from yellow to red (warning) above 27℃, and shows white when the front door opens for maintenance. Linked to a top-mounted infrared sensor, the light strip activates when someone approaches and turns off 5 minutes after they leave.
Read More -
Configuration Parameters Overall system parameters Number of cabinets supported by a single module 1-12 cabinets Maximum available space 420U (12 cabinets, excluding battery pack, load 54kW) Channel Type Single-row channel, natural heat dissipation/enclosed cold channel/enclosed hot and cold channel Power density range 3-8kW/cabinet Battery deployment method Battery packs, battery cabinets, battery racks Battery backup time 15min-240min Installation Concrete floor, raised floor Power supply type Single-phase three-wire/three-phase five-wire System protection level IP20 (mesh door) / IP50 (glass door) Operating temperature -20C-45℃ altitude If the distance exceeds 1000m, the rating needs to be reduced. Cabinet System Natural cooling (N*600)*1200*2000mm, excluding casters and adjustable feet, front and rear high-density ventilation mesh doors, n is the number of cabinets Closed Cold Aisles (N*600)*1200*2000mm, excluding casters and adjustable feet, front glass door, rear mesh door, n is the number of cabinets Closed hot and cold aisles (N*600)*1400*2000mm, excluding casters and adjustable feet, front and rear glass doors. n is the number of cabinets IP Rating IP20 (mesh door) / IP50 (glass door) Refrigeration system Input Power 220Vac Cooling capacity (single air conditioner) 4.5kW(4U)/8kW(10U)/15kW(12U)/30kW(21U) Air conditioning configuration 1+0, 1+1, 2+0, 2+1, 3+0, 3+1 (optional) Sensible heat ratio (sensible cooling capacity/total cooling capacity) 1 refrigerant R410A Air supply method Front air supply, rear air return Installation Rack Mount Power supply and distribution system Power Input Single-phase three-wire/three-phase five-wire UPS capacity 3kVA/6kVA/10kVA/20kVA UPS Configuration N, N+1 UPS rated input voltage 220Vac/230Vac/240Vac single phase; 380Vac/400Vac/415Vac three phase UPS input voltage range 80Vac~280Vac single phase: 138Vac~485Vac three phase UPS output power factor 0.8/0.9 UPS rated output voltage 220Vac/230Vac/240Vac single phase; 380Vac/400Vac/415Vac three phase UPS overall efficiency 92%/95% Maintenance bypass support Number of mains feed-out channels 4-way IT + 4-way air conditioning and fire protection / 12-way IT + 5-way air conditioning and fire protection UPS feed-out number 4-way IT/12-way IT AC lightning protection B and C grades Monitoring system Monitoring system host Support embedded Web direct access Local interface 10.1 inch industrial touch panel Leaking Rope Standard Smoke Standard Temperature and humidity Standard Automatic door opening device Optional Door sensor Optional Power supply/UPS/air conditioning monitoring Standard Northbound communication interface Optional Protocol Format SNMP SMS alarm Optional Emergency fan Optional Cabinet light strip Standard Fire protection system Heptafluoropropane gas fire fighting module 1U rack-mount installation, single module can manage two cabinets (optional) Read More -