Wall-mounted Wind Wall High-energy Air Conditioning Units

30.2kW ~ 300.1kW ; 7000 ~ 56000m³/h
Overviews
High Density Cooling Solutionfor Large Scale Data Center, low noise operation, modular prefabrication, and fan redundancy, these units address data center energy and space challenges. Ideal for both new installations and retrofits, they are suitable for data centers, communication hubs, computer rooms, and control centers, ensuring reliable cooling performance.
  • Features

  • Specifications

  • Applications

  • Download

High Energy Efficiency​

The unit integrates variable air volume and water flow control with hot-cold channel isolation, enabling energy-efficient operation. With multiple operating modes, it automatically selects the optimal setting based on indoor and outdoor conditions, effectively lowering the data center’s PUE value.​

Structural Design​

Featuring a novel design, the unit embeds high-capacity cooling coils and fans within the data center’s isolation wall, creating a sealed hot air return channel. Its three-dimensional front facade offers a sleek appearance. The separation of cooling coils and fans into independent modules expands the size and specification options.​

Modular Prefabrication​

Designed modularly, each wind wall unit can operate independently or be combined flexibly. Boasting high cooling capacity, these units allow easy addition or removal of modules, adapting seamlessly to changing room loads.

Redundant Design

The fan redundant design can meet different cooling requirements and is easy to install and maintain.

DC FAN

It uses high-efficiency DC fans, which have the advantages of energy saving, low noise, and continuously adjustable air volume.

Electric two-way valve

Adopt first-line brand, product performance is excellent, high sensitivity, easy to replace, and effective in regulating water flow.

Cold water coil

Use I-shaped cold water coil to increase the heat exchange area and make the airflow more uniform.

Read More

FO. GBE Modular Fan Wall Unit Parameters

Model
FO. GBE
Unit 1500 R-H 2000 R-H 2500 R-H 3000 R-H
Cooling Conditions   37°C-30%RH 37°C-30%RH 27°C-30%RH 37°C-30%RH
Total Cooling Capacity kW 150.1 200.1 250.1 300.1
Sensible Cooling Capacity kW 150.1 200.1 250.1 300.1
Inlet/Outlet Water Temp °C 15/21 15/21 15/21 15/21
Water Flow Rate m³/h 21.51 28.68 35.84 43.01
Pressure Drop kPa 115 120 125 130
EC Fan
Quantity pcs 4 4 4 6
Air Supply Volume m³/h 35000 40000 49000 56000
Residual Pressure Pa 200
Rated Power kW 7 8 10.1 13.2
Dimensions
Length mm 2400 2400 3000 3000
Width mm 1100 1100 1100 1100
Height mm 2150 2150 2150 2150
Connections DN 65 65 65 65
Electrical Parameters
Input Power 380V±10%50HZ±3HZ

 

FO. WL Wind Wall Air Conditioning Unit Parameters

Parameter Unit FO.WL-600 FO.WL-300
Cooling Conditions   37°C-30%RH 37°C-30%RH
Total Cooling Capacity kW 60.1 30.3
Sensible Cooling Capacity kW 60.1 30.3
Inlet/Outlet Water Temp °C 18/24 18/24
Water Flow Rate m³/h 8.61 4.32
Pressure Drop kPa 61 41
EC Fan
Quantity pcs 78 39
Air Supply Volume m³/h 14 70
Raised Power kW 1.04 0.39
Dimensions
Length mm 1200 600
Width mm 2000 2000
Height mm 2200 2200
Weight kg 165 95
Connections DN 32 32
Electrical Parameters
Input Power - 220V ±10% 50Hz ±3Hz
Read More
  • Innovative Energy-saving Data Center
    The wind wall unit is combined with the building structure of the computer
    room, and a fan matrix air supply form can be adopted, which fully utilizes the
    advantages of closed cold and hot channels, with high density and low energy
    consumption.
  • Energy-saving Transformation of Data Centers
    The combination of the computer room structure and the heat dissipation system
    can adopt direct fresh air or a mixed solution of fresh air and return air cooling.
    The airflow organization of the wind wall is better and the heat exchange effect is
    better. Under the same cooling demand, the air volume demand is reduced, the
    fan power consumption is further reduced, and the energy saving effect can reach
    more than 10%.
  • Data Center with Coordinated Building Structure Design
    Combined with the characteristics of the building structure, a variety of personalized
    structural forms can be adopted to cooperate with the overall designed data center.
  • Areas with Low Temperatures All Year Round
    According to the characteristics of low temperature, the wind wall unit system can
    adopt fresh air direct cooling, fresh air return air mixed cooling, and fresh air
    indirect evaporative cooling for better energy saving effect.